#811
Before I move to shed walls I need to get zero height (triangular) gable walls up and running.

Which is the preferred configuration (left or right) of the bottom and top plates?

#812
Version 1.5.4c - 07.10.2020
- Fixed a bug in the gable wall draw menu for metric templates.

*** Critical Bug Fix ***

Download this update in order to utilize gable walls with metric templates.
#813
Version 1.5.4b - 07.10.2020
- Fixed a bug with the wall move tool when moving gable walls.
- Added tee intersection blocking for gable walls: 3-stud, 2-stud, 2-stud w/ blocking, ladder blocking.
- Enabled auto-corner configuration for gable walls.

#814
Working on tee intersection blocking for gable walls:





#815
I now need to turn my attention briefly the shed wall variant of the gable wall.

Unlike the standard gable wall the shed wall will only have one wall height (low side) and one wall pitch however it can be a left or right handed shed wall.
#816
Version 1.5.4 - 07.08.2020
- Added the gable wall tool with the ability to draw and edit standard gable walls.



Be advised this is a completely new module with modifications to over 36 files (ruby and html).  I have tested most of the features with the gable walls however I am quite positive that further testing will pull out a few bugs or limitations which will need to be rectified.

Please feel free to test out the new gable wall module and report any bugs or other issues that may arise.

The following limitations currently exist and are subject to change in the near future:

- The gable wall cannot be used with the wall "move" tool yet.  The results might be unpredictable.
- Gable walls are limited to orthogonal corners (90 degrees).
- Auto-corner configuration is turned off for gable walls, the user can edit the wall once it is created and set the start and end termination conditions.
- I will need to add in additional logic for the case of zero wall height (triangular gable walls).
- Currently there is no method from switch a gable wall to a rectangular wall.
- Termination conditions are:  Outside Corner, Inset Outside Corner, End, Terminal, Tee Corner.
#817
Okay, so I don't have the inset outside corner quite right for the gable wall:



I need to adjust it so that it terminates at the plate height of the intersecting rectangular wall, a minor change.

I am still tossing around the auto-corner configuration routines, not sure yet on the final path I will take, it may just be easier to initially disable this for gable walls and require the user to manually set their wall termination configurations.

I will also update the draw tool to only allow the drawing of a single gable wall panel at a time.
#818
Gable walls with exterior trim (frieze, band, skirt, corners):



The intersection of the frieze board with the corner trim is still a bit of a question for me especially if the frieze were to cut through the corner trim.

View model here:

https://3dwarehouse.sketchup.com/model/4383fd71-360a-4799-b6b8-3d0c374514ec/Gable-Wall-1
#819
Beam pocket cutouts for gypsum, sheathing and cladding:



In the situation where the cutout bisects the peak (as shown) the cutout piece is a pentagon not a trapezoid, needed to rework my logic a bit to take care of that situation.

Now I've only got the exterior trim to work on and possibly some more testing with the following items:

- corner configurations/terminations (make sure they all work as expected).
- adjust auto-corner configurations or disable entirely for the gable wall type.
- tee intersections, what are the possible permutations?
- change from polyline to single panel construction for the draw tool, still thinking about this one.
#820
Gable wall with cladding and quoins:

#821
Gysum (two layers) applied to an interior gable wall:

#822
Gable wall with sheathing:

#823
A CMU gable wall:



The texture/material on the inclined surfaces is representational at best.
#824
A WSW Simpson Strong-Wall trimmed to an incline to fit within a gable wall.  I've been looking forward to this day ever since I utilized one of these shear wall panels within one of my own residential designs about four years ago.



Note that only the WSW series can be field trimmed like this, at least to my knowledge.  I need to do a bit more research into what Simpson recommends for an SSW installation when the top plate is inclined or if this is even possible.  I suppose one could always install a trapezoidal block between the SSW and the top plate.

Next I will look at the sheathing, cladding and gypsum and also sort out more of the details with the inset outside corner (termination).
#825
We're not out of the woods yet:



The WSW series is field trimmable (to an incline), so we can set that up if this type of pre-manufactured shearwall is selected. I also need to add some extra logic in for the optional king studs and the symbol on top of the wall.